First year results of a randomized study of 1509 users of the Copper T380Ag with a silver core or of an IUD releasing 20 mcg day of levonorgestrel are reported. The cumulative gross pregnancy rate for each device was 0.3 per 100 at one year, with more than 490 women having one year of use with each device. The levonorgestrel-releasing device was associated with significantly fewer bleeding days and significantly increased hemoglobin levels when compared with pre-admission values or the one year values observed among users of the TCu380Ag. Terminations attributable to amenorrhea were significantly more frequent among users of the levonorgestrel-releasing device. The TCu 380Ag was associated with increased frequency and severity of dysmenorrhea compared with pre-admission levels or with the steroid-releasing device. Hemoglobin levels were somewhat reduced among users of the TCu 380Ag device. Terminations attributable to pain were, however, not significantly different by device. Continuation rates at the end of the first year were not significantly different by device.
copper IUD versus levonorgestrel IUD randomized trial, TCu 380Ag levonorgestrel 20 mcg IUD comparison, intrauterine device bleeding patterns hemoglobin levels, levonorgestrel IUD amenorrhea side effects, copper IUD dysmenorrhea hemoglobin reduction, Sivin IUD randomized multicenter study, IUD continuation rates first year comparison, intrauterine contraception pregnancy rates copper levonorgestrel, hormonal versus non-hormonal IUD bleeding outcomes, Mirena copper T IUD early clinical trial
PMID 6440740 6440740 DOI 10.1016/0010-7824(84)90036-2 10.1016/0010-7824(84)90036-2
Cite this article
Sivin, I., Alvarez, F., Díaz, M., Díaz, M., Mahgoub, S. E., Coutinho, E. M., Brache, V., Díaz, M., Pavez, M., & et al. (1984). Intrauterine contraception with copper and with levonorgestrel: a randomized study of the TCu 380Ag and levonorgestrel 20 mcg/day devices. *Contraception*, *30*(5), 443-456. https://doi.org/10.1016/0010-7824(84)90036-2
Sivin I, Alvarez F, Díaz M, Díaz M, Mahgoub SE, Coutinho EM, et al. Intrauterine contraception with copper and with levonorgestrel: a randomized study of the TCu 380Ag and levonorgestrel 20 mcg/day devices. Contraception. 1984;30(5):443-456. doi:10.1016/0010-7824(84)90036-2
Sivin, Irving, et al. "Intrauterine contraception with copper and with levonorgestrel: a randomized study of the TCu 380Ag and levonorgestrel 20 mcg/day devices." *Contraception*, vol. 30, no. 5, 1984, pp. 443-456.
Objective: To examine trends in national reporting of broken intrauterine devices (IUDs).
Study Design: We enumerated IUD device "breakage" reports in the Food and Drug Administration Adverse Event R...
Objective: To evaluate overall and subgroup efficacy of an estetrol (E4) 15 mg drospirenone (DRSP) 3 mg oral contraceptive in a 24/4-day regimen.
Study Design: We pooled efficacy outcomes from 2 pivo...
Objective: The Natural Cycles app employs daily basal body temperature to define the fertile window via a proprietary algorithm and is clinically established effective in preventing pregnancy. We soug...
Objectives: To summarize the evidence on typical and perfect-use effectiveness of fertility awareness-based methods for avoiding pregnancy during the postpartum period, whether breastfeeding or not.
...