Rifai, N., Tracy, R. P., & Ridker, P. M. (1999). Clinical efficacy of an automated high-sensitivity C-reactive protein assay. Clinical Chemistry, 45(12), 2136-2141. https://doi.org/10.1093/clinchem/45.12.2136
Rifai N, Tracy RP, Ridker PM. Clinical efficacy of an automated high-sensitivity C-reactive protein assay. Clin Chem. 1999;45(12):2136-2141. doi:10.1093/clinchem/45.12.2136
Rifai, Nader, et al. "Clinical efficacy of an automated high-sensitivity C-reactive protein assay." Clinical chemistry, vol. 45, no. 12, 1999, pp. 2136-2141.
For EndNote, Zotero or Mendeley:
License
No open license is recorded for this paper. Reuse terms are set by the publisher.
Prospective studies have shown that C-reactive protein (CRP) can be used to predict risk of future cardiovascular events. High-sensitivity methods for CRP (hs-CRP) measurement are needed for this purpose.
Methods
We compared the clinical efficacy of an automated and commercially available latex-enhanced assay (Latex) for hs-CRP (Dade Behring) to a validated in-house ELISA, previously shown to predict future peripheral arterial disease (PAD) in asymptomatic populations. Using a prospective, nested, case-control design, we measured baseline hs-CRP concentrations in 144 apparently healthy men who subsequently developed symptomatic PAD and 144 age- and smoking habit-matched controls who remained free of vascular disease over the follow-up period of 60 months.
Results
The two hs-CRP assays correlated highly (r = 0.95; P <0.001), and all but two participants were classified into concordant quartiles or varied by only one quartile. The median hs-CRP of the case group was significantly higher than that of controls when measured by either the ELISA (1.34 vs 0.99 mg/L; P = 0.034) or the Latex method (1.80 vs 1.20 mg/L; P = 0.042). Furthermore, for both ELISA and the Latex method, the calculated relative risks of developing PAD increased significantly with each increasing quartile of hs-CRP. The calculated interquartile increase in relative risk of PAD was 31% (95% confidence interval, 5.2-62.2%; P = 0.01) for ELISA and 34% (95% confidence interval, 8.2-66.1%; P = 0.007) for the Latex method.
Conclusions
Our findings indicate that the Latex method is equally as efficacious as the validated ELISA in classifying patients into cutoff points established by prospective studies for risk stratification for coronary and cerebrovascular disease.
Rahmioglu N et al., 2023·Nat Genet·Free full text on PubMed Central
Endometriosis is a common condition associated with debilitating pelvic pain and infertility. A genome-wide association study meta-analysis, including 60,674 cases and 701,926 controls of European and East Asian descent, identified 42 genome-wide significant loci comprising 49 distinct association signals. Effect sizes were largest for stage 3/4 disease, driven by ovarian endometriosis. Identified signals explained up to 5.01% of disease variance and regulated expression or methylation of genes in endometrium and blood, many of which were associated with pain perception/maintenance (SRP14/BMF, GDAP1, MLLT10, BSN and NGF). We observed significant genetic correlations between endometriosis and 11 pain conditions, including migraine, back and multisite chronic pain (MCP), as well as inflammatory conditions, including asthma and osteoarthritis. Multitrait genetic analyses identified substantial sharing of variants associated with endometriosis and MCP/migraine. Targeted investigations of genetically regulated mechanisms shared between endometriosis and other pain conditions are needed to aid the development of new treatments and facilitate early symptomatic intervention.
Measurement and Statistics · Instrument Development and Validation
C-reactive protein (CRP) can provide prognostic information about the risk of developing atherosclerotic complications in apparently healthy patients. This new clinical application requires quantification of CRP concentrations below those traditionally measured in the clinical laboratory. The Dade Behring BN II, the Abbott IMx, the Diagnostic Products Corporation IMMULITE, and the Beckman Coulter IMMAGE are four automated analyzers with high-sensitivity CRP (hs-CRP) methods. We evaluated these assays for precision, linearity, and comparability with samples from 322 apparently healthy blood donors. The imprecision (CV) of the BN II, IMx, IMMULITE, and IMMAGE methods was < or = 7.6%, < or = 12%, < or = 9.8%, and < or = 9.7% at 3.5 mg/L, respectively. The BN II, IMx, IMMULITE, and IMMAGE methods were linear down to < or = 0.30, < or = 0.32, < or = 0.85, and 2.26 mg/L, respectively. CRP concentrations demarcating each quartile in a healthy population were method dependent. The IMx method gave results comparable to the BN II method for values in the reference interval. The IMMULITE method had a positive intercept compared with the BN II method. The IMMAGE method demonstrated more scatter and a positive intercept compared with the BN II method, which may reflect the fact that it is a less sensitive assay. The four hs-CRP methods exhibited differences in results for a healthy population. Additional standardization efforts are required to ensure that hs-CRP results can be related to large-scale epidemiologic studies.
Research Methods › Measurement and Statistics › Instrument Development and Validation
Paul M Ridker
P Ridker
PMID 10585345 10585345 DOI 10.1093/clinchem/45.12.2136 10.1093/clinchem/45.12.2136 Rifai et al. 1999, Rifai 1999
Cite this article
Rifai, N., Tracy, R. P., & Ridker, P. M. (1999). Clinical efficacy of an automated high-sensitivity C-reactive protein assay. Clinical Chemistry, 45(12), 2136-2141. https://doi.org/10.1093/clinchem/45.12.2136
Rifai N, Tracy RP, Ridker PM. Clinical efficacy of an automated high-sensitivity C-reactive protein assay. Clin Chem. 1999;45(12):2136-2141. doi:10.1093/clinchem/45.12.2136
Rifai, Nader, et al. "Clinical efficacy of an automated high-sensitivity C-reactive protein assay." Clinical chemistry, vol. 45, no. 12, 1999, pp. 2136-2141.