Assisted Reproduction · Safety and Risks

Obstetric and neonatal outcomes after natural versus artificial cycle frozen embryo transfer and the role of luteal phase support: a systematic review and meta-analysis

Zaat TR, Kostova EB, Korsen P, Showell MG, Mol F, van Wely M

Published September 5, 2023 Human reproduction update, 29(5), 634-654
DOI 10.1093/humupd/dmad011 PMID 37172270 PMC PMC10477943

RRM Academy Synopsis

Fewer preterm births follow natural cycle frozen embryo transfer

A review that pooled 30 observational studies of live births after frozen embryo transfer found natural cycle transfer carried lower odds of preterm birth and pre-eclampsia than artificial cycle transfer. The studies covered 113 676 live births. Bleeding after delivery and early pregnancy loss also had lower odds, on very low to low quality evidence.

Key Findings

  • Pooling 30 cohort studies of live births after frozen embryo transfer, natural cycle transfer (NC-FET) had lower odds of preterm birth than artificial cycle transfer (AC-FET) (OR 0.80; 95% CI 0.75–0.85).
  • Hypertensive disorders of pregnancy were less frequent after NC-FET (OR 0.60, 95% CI 0.50–0.65). Pre-eclampsia showed an odds ratio of 0.50 (95% CI 0.42–0.60).
  • Postpartum hemorrhage had an odds ratio of 0.43 (95% CI 0.38–0.48), and early pregnancy loss 0.73 (95% CI 0.61–0.86), both lower after NC-FET. Large for gestational age had OR 0.88 (95% 0.83–0.94).
  • Stratified analysis suggested lower preterm birth risk for NC-FET with luteal phase support than AC-FET (OR 0.75, 95% CI 0.70–0.81; very low quality), but not without it (OR 0.96, 95% CI 0.82–1.11).
  • The two groups were similar for gestational diabetes (OR 1.01, 95% CI 0.85–1.19). Congenital malformations had an odds ratio of 0.86 (95% CI 0.66–1.11), and neonatal mortality 0.80 (95% CI 0.56–1.13).

Interpretation

Most of the 30 studies were retrospective cohorts, so the pooled results describe associations. The authors could not adjust for confounders in the main analysis. They rated the evidence very low to moderate in quality. Seventeen studies included women with irregular cycles or no ovulation. The authors call the luteal phase support result possibly spurious. Both groups had IVF embryo transfers, so the findings describe risks inside IVF.

RRM Context

The authors name the missing corpus luteum as one possible reason for more high blood pressure disorders after artificial cycles. The corpus luteum forms after ovulation, and artificial cycles suppress ovulation. Two studies they cite could not detect relaxin, a corpus luteum hormone that acts on blood vessels, in early pregnancies from artificial cycles. This fits the restorative reproductive medicine principle of working with the ovulatory cycle.

Abstract

Background

The number of frozen embryo transfers (FET) has increased dramatically over the past decade. Based on current evidence, there is no difference in pregnancy rates when natural cycle FET (NC-FET) is compared to artificial cycle FET (AC-FET) in subfertile women. However, NC-FET seems to be associated with lower risk of adverse obstetric and neonatal outcomes compared with AC-FET cycles. Currently, there is no consensus about whether NC-FET needs to be combined with luteal phase support (LPS) or not. The question of how to prepare the endometrium for FET has now gained even more importance and taken the dimension of safety into account as it should not simply be reduced to the basic question of effectiveness.

Objective and Rationale

The objective of this project was to determine whether NC-FET, with or without LPS, decreases the risk of adverse obstetric and neonatal outcomes compared with AC-FET.

Search Methods

A systematic review and meta-analysis was carried out. A literature search was performed using the following databases: CINAHL, EMBASE, and MEDLINE from inception to 10 October 2022. Observational studies, including cohort studies, and registries comparing obstetric and neonatal outcomes between singleton pregnancies after NC-FET and those after AC-FET were sought. Risk of bias was assessed using the ROBINS-I tool. The quality of evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation approach. We calculated pooled odds ratios (ORs), pooled risk differences (RDs), pooled adjusted ORs, and prevalence estimates with 95% CI using a random effect model, while heterogeneity was assessed by the I2.

Outcomes

The conducted search identified 2436 studies, 890 duplicates were removed and 1546 studies were screened. Thirty studies (NC-FET n = 56 445; AC-FET n = 57 231) were included, 19 of which used LPS in NC-FET. Birthweight was lower following NC-FET versus AC-FET (mean difference 26.35 g; 95% CI 11.61-41.08, I2 = 63%). Furthermore NC-FET compared to AC-FET resulted in a lower risk of large for gestational age (OR 0.88, 95% 0.83-0.94, I2 = 54%), macrosomia (OR 0.81; 95% CI 0.71-0.93, I2 = 68%), low birthweight (OR 0.81, 95% CI 0.77-0.85, I2 = 41%), early pregnancy loss (OR 0.73; 95% CI 0.61-0.86, I2 = 70%), preterm birth (OR 0.80; 95% CI 0.75-0.85, I2 = 20%), very preterm birth (OR 0.66, 95% CI 0.53-0.84, I2 = 0%), hypertensive disorders of pregnancy (OR 0.60, 95% CI 0.50-0.65, I2 = 61%), pre-eclampsia (OR 0.50; 95% CI 0.42-0.60, I2 = 44%), placenta previa (OR 0.84, 95% CI 0.73-0.97, I2 = 0%), and postpartum hemorrhage (OR 0.43; 95% CI 0.38-0.48, I2 = 53%). Stratified analyses on LPS use in NC-FET suggested that, compared to AC-FET, NC-FET with LPS decreased preterm birth risk, while NC-FET without LPS did not (OR 0.75, 95% CI 0.70-0.81). LPS use did not modify the other outcomes. Heterogeneity varied from low to high, while quality of the evidence was very low to moderate.

Wider Implications of the Findings

This study confirms that NC-FET decreases the risk of adverse obstetric and neonatal outcomes compared with AC-FET. We estimate that for each adverse outcome, use of NC-FET may prevent 4 to 22 cases per 1000 women. Consequently, NC-FET should be the preferred treatment in women with ovulatory cycles undergoing FET. Based on very low quality of evidence, the risk of preterm birth be decreased when LPS is used in NC-FET compared to AC-FET. However, because of many uncertainties-the major being the debate about efficacy of the use of LPS-future research is needed on efficacy and safety of LPS and no recommendation can be made about the use of LPS.

Topics

By this author

Related research

Assisted Reproduction › Safety and Risks › Neonatal and Birth Outcomes · Pregnancy › Neonatal Outcomes › Neonatal Morbidity · Birth and Delivery › Birth Outcomes › Maternal Morbidity
Madelon van Wely
M Wely
PMID 37172270 37172270 DOI 10.1093/humupd/dmad011 10.1093/humupd/dmad011 Zaat et al. 2023, Zaat 2023