General Gynecology · Infections

Elevated Risk of Bacterial Vaginosis Among Users of the Copper Intrauterine Device: A Prospective Longitudinal Cohort Study

Peebles K, Kiweewa FM, Palanee-Phillips T, Chappell C, Singh D, Bunge KE, Naidoo L, Makanani B, Jeenarain N, Reynolds D, Hillier SL, Brown ER, Baeten JM, Balkus JE, MTN-020/ASPIRE study team

Published August 2, 2021 Clinical infectious diseases : an official publication of the Infectious Diseases Society of America, 73(3), 513-520
DOI 10.1093/cid/ciaa703 PMID 32505132 PMC PMC8326546

Abstract

Background

Limited evidence suggests that the nonhormonal contraceptive copper intrauterine device (Cu-IUD) may increase bacterial vaginosis (BV) risk, possibly due to increased volume and duration of menses, a common side effect of Cu-IUD use. Although increases in bleeding typically resolve within 6-12 months following initiation, evaluations of the association between Cu-IUD and BV have not included more than 6 months of follow-up.

Methods

This secondary analysis of a human immunodeficiency virus type 1 prevention trial included 2585 African women ages 18-45 followed for up to 33 months. Women reported contraceptive use each month. BV was evaluated by Nugent score in 6-monthly intervals and, if clinically indicated, by Amsel criteria. Andersen-Gill proportional hazards models were used to (1) evaluate BV risk among Cu-IUD users relative to women using no/another nonhormonal contraceptive and (2) test changes in BV frequency before, while using, and following Cu-IUD discontinuation.

Results

BV frequency was highest among Cu-IUD users at 153.6 episodes per 100 person-years (95% confidence interval [CI]: 145.2, 162.4). In adjusted models, Cu-IUD users experienced 1.28-fold (95% CI: 1.12, 1.46) higher BV risk relative to women using no/another nonhormonal contraception. Compared to the 6 months prior to initiation, BV risk was 1.52-fold (95% CI: 1.16, 2.00) higher in the first 6 months of Cu-IUD use and remained elevated over 18 months of use (P < .05). Among women who discontinued Cu-IUD, BV frequency was similar to pre-initiation rates within 1 year.

Conclusions

Cu-IUD users experienced elevated BV risk that persisted throughout use. Women and their providers may wish to consider BV risk when discussing contraceptive options.

Topics

By this author

Related research

General Gynecology › Infections › Vaginal and Cervical Infections · Contraception › Long Acting Methods › Intrauterine Devices · Infections and the Reproductive Microbiome › Vaginal and Cervical Flora › Bacterial Vaginosis
Jared M Baeten
J Baeten
PMID 32505132 32505132 DOI 10.1093/cid/ciaa703 10.1093/cid/ciaa703 Peebles et al. 2021, Peebles 2021

Cite this article

Peebles, K., Kiweewa, F. M., Palanee-Phillips, T., Chappell, C., Singh, D., Bunge, K. E., Naidoo, L., Makanani, B., Jeenarain, N., Reynolds, D., Hillier, S. L., Brown, E. R., Baeten, J. M., Balkus, J. E., & MTN-020/ASPIRE study team (2021). Elevated Risk of Bacterial Vaginosis Among Users of the Copper Intrauterine Device: A Prospective Longitudinal Cohort Study. Clinical infectious diseases : an official publication of the Infectious Diseases Society of America, 73(3), 513-520. https://doi.org/10.1093/cid/ciaa703