Adhesion Prevention · Barrier Agents
Haney AF et al., 1995 · Fertil Steril
To compare the impact of expanded polytetrafluoroethylene (PTFE; Gore-Tex Surgical Membrane; W. L. Gore & Associates, Inc., Flagstaff, AZ) and oxidized regenerated cellulose (Interceed TC7, Johnson & Johnson Medical, Inc., Arlington, TX) on the development of postsurgical adhesions. A multicenter, nonblinded, randomized clinical trial. University medical centers. Each barrier was allocated randomly to the left or right sidewall of every patient. Thirty-two women with bilateral pelvic sidewall adhesions undergoing reconstructive surgery and second-look laparoscopy. Adhesion score (on a 0- to 11-point scale), the area of adhesion (cm2), and the likelihood of no adhesions. The use of both barriers was associated with a lower adhesion score and area of adhesion postoperatively. However, those sidewalls covered with PTFE had a significantly lower adhesion score (0.97 +/- 0.30 versus 4.76 +/- 0.61 points, mean +/- SEM) and area of adhesion (0.95 +/- 0.35 versus 3.25 +/- 0.62 cm2). Overall, more sidewalls covered with PTFE had no adhesions (21 versus 7) and, when adhesions were present on the contralateral sidewall, the number of sidewalls covered with PTFE without adhesions was greater than those covered with oxidized regenerated cellulose (16 versus 2). Expanded polytetrafluoroethylene was associated with fewer postsurgical adhesions to the pelvic sidewall than oxidized regenerated cellulose.
Adhesion Prevention · Barrier Agents
Haney AF et al., 1993 · Fertil Steril
To evaluate the ability of the two currently available surgical barriers, oxidized regenerated cellulose and expanded-polytetrafluoroethylene (PTFE), to prevent postsurgical adhesions.
Murine uterine horns were approximated in the midline and the contacting uterine surfaces injured by electrocautery, cutting, and scratching, with and without barriers interposed. Sham-operated and experimental animals had adhesions assessed visually and histologically 7 days postoperatively. In another group, adhesions were created and then lysed 7 days later with barriers interposed. Readhesion formation was assessed 14 days after lysis with the PTFE being removed 7 days after lysis.
Research laboratory Adhesions occurred at 58.5% of the electrocautery sites without barriers, 100% of the readhesion sites with recautery for hemostasis, and 92% of the recautery sites without hemostasis. None of the sham-operated sites developed adhesions. When oxidized regenerated cellulose was interposed, adhesions were observed at 36% of uninjured uterine horn sites, 62% with single and 92% with double electrocautery injuries and 90% of the reformation sites. The PTFE did not cause adhesions in uninjured controls and completely prevented adhesion formation and reformation, regardless of the type of injury or whether hemostasis was achieved. A thin cellular membrane, continuous with the uterine serosa, enveloped the PTFE. Expanded-polytetrafluoroethylene, but not oxidized regenerated cellulose, prevents adhesion formation and reformation in this murine uterine horn model. Additionally, oxidized regenerated cellulose was adhesiogenic even without surgical injury.
Adhesion Prevention · Barrier Agents
Haney AF et al., 1992 · Am J Obstet Gynecol
The peritoneal fluid cell responses to the available barriers used to prevent postoperative adhesions, oxidized regenerated cellulose (interceed) and expanded polytetrafluoroethylene (Gore-Tex Surgical Membrane), were compared. Oxidized regenerated cellulose and expanded polytetrafluoroethylene were inserted into the peritoneal cavity of mice and the peritoneal fluid cell number, differential cell count, morphologic type, adherence to plastic, and phorbol-12,13-myristate acetate-stimulated hydrogen peroxide production evaluated. Peritoneal fluid cell attachment to oxidized regenerated cellulose and expanded polytetrafluoroethylene was evaluated by electron microscopy. Oxidized regenerated cellulose promptly elicited increased numbers of large, morphologically activated peritoneal fluid macrophages that adhered more rapidly and produced more hydrogen peroxide than controls. Expanded polytetrafluoroethylene gradually increased the number of normal-appearing peritoneal fluid macrophages with increased hydrogen peroxide production but normal adherence. Macrophages rapidly attached to both materials in vivo, with oxidized regenerated cellulose being rapidly degraded. Oxidized regenerated cellulose, to a greater extent than expanded polytetrafluoroethylene, elicits an acute peritoneal fluid inflammatory exudate in the mouse, which may contribute to the oxidized regenerated cellulose-induced peritoneal injury and de novo adhesions observed in this model.
Adhesion Prevention · Barrier Agents
Haney AF et al., 1992 · Fertil Steril
To evaluate the impact of the materials contained in the available adhesion prevention barriers on the peritoneum. STUDY DESIGN, SETTING, A murine paradigm was used, placing oxidized-regenerated cellulose (Interceed [TC7]) and expanded polytetrafluoroethylene (PTFE; Gore-Tex Surgical Membrane) in the peritoneal cavity for intervals up to 14 days. MAIN The appearance of the peritoneum on scanning and transmission electron microscopy and the presence of de novo adhesions were the end-points used. Oxidized-regenerated cellulose caused localized sloughing of the mesothelial cell layer and leukocyte infiltration of the deeper tissue leading to the formation of adhesions to the bowel and liver in 58% of the animals. The surface of the oxidized-regenerated cellulose-injured peritoneum healed in 5 to 7 days. Neither peritoneal injury nor adhesions were noted in sham-operated animals or animals with PTFE. Oxidized-regenerated cellulose but not PTFE has a localized injurious effect on the peritoneum of the mouse, resulting in de novo adhesions. The impact of the barrier material itself on normal peritoneum may be an important consideration in designing surgical barriers for the prevention of postoperative adhesions.